PNOZ sigma safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, manual/automatic start, outputs: 2 N/O, 1 SC, UB 24 V DC, width: 17.5 mm, plug-in plug-in terminals of screw type, monitoring of E-STOP, safety gates, light guard.

The 750103 is a Safety Relay for monitoring E-STOP pushbuttons, safety gates and light beam devices. A connector can be used to connect 1 PNOZsigma contact expander module. Operating modes can be set via rotary switch. LED indicator for Supply voltage, Input status channel 1, Input status channel 2, Switch status channel 1/2, Reset circuit and Error. Plug-in connection terminals (either spring-loaded terminal or screw terminal). The correct opening and closing of the safety function relays is tested automatically in each on-off cycle. The circuit is redundant with built-in self-monitoring.

  • Positive-guided relay outputs
  • Circuit is redundant with built-in self-monitoring

Applications:
  • Industrial, Power Management, Automation & Process Control

TECHNICAL DATA

DOWNLOADS

PILZ 750103 | PNOZ s3 24VDC 2 no | Relay

Product ID: 750103

PNOZ sigma safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, manual/automatic start, outputs: 2 N/O, 1 SC, UB 24 V DC, width: 17.5 mm, plug-in plug-in terminals of screw type, monitoring of E-STOP, safety gates, light guard.

The 750103 is a Safety Relay for monitoring E-STOP pushbuttons, safety gates and light beam devices. A connector can be used to connect 1 PNOZsigma contact expander module. Operating modes can be set via rotary switch. LED indicator for Supply voltage, Input status channel 1, Input status channel 2, Switch status channel 1/2, Reset circuit and Error. Plug-in connection terminals (either spring-loaded terminal or screw terminal). The correct opening and closing of the safety function relays is tested automatically in each on-off cycle. The circuit is redundant with built-in self-monitoring.

  • Positive-guided relay outputs
  • Circuit is redundant with built-in self-monitoring

Applications:
  • Industrial, Power Management, Automation & Process Control

TECHNICAL DATA

DOWNLOADS

Sign up for our newsletter

We only use your email address to add you to our mailing list for receiving our newsletters(monthly). This information is only kept in our mailing list and not for any other purposes than for contacting you with our newsletters.

Thank you for your submission! You will hear from us soon.